+38 (093) 333-86-19 +38 (063) 250-22-00
+38 (093) 333-86-03 +38 (093) 333-86-87

CS13,6


Warning: Use of undefined constant b - assumed 'b' (this will throw an Error in a future version of PHP) in /home/boooeller/web/beton-nova.com.ua/public_html/wp-content/themes/contractor-pro/functions.php on line 173

Warning: Use of undefined constant c - assumed 'c' (this will throw an Error in a future version of PHP) in /home/boooeller/web/beton-nova.com.ua/public_html/wp-content/themes/contractor-pro/functions.php on line 175

Warning: Use of undefined constant c - assumed 'c' (this will throw an Error in a future version of PHP) in /home/boooeller/web/beton-nova.com.ua/public_html/wp-content/themes/contractor-pro/functions.php on line 175
ТУ У - В.2.6-26.6 – 34406629 – 001:2008

Warning: Use of undefined constant c - assumed 'c' (this will throw an Error in a future version of PHP) in /home/boooeller/web/beton-nova.com.ua/public_html/wp-content/themes/contractor-pro/functions.php on line 175

Warning: Use of undefined constant c - assumed 'c' (this will throw an Error in a future version of PHP) in /home/boooeller/web/beton-nova.com.ua/public_html/wp-content/themes/contractor-pro/functions.php on line 175
Код ОКП - 58 6311

Stands concrete centrifuged (conical) 13,6 m long for the supports contact-term railway network.

Developed by All-Russia Research Institute of Railway Transport. Adopted by the international scientific-technical Commission ISTC dated 20.05.1999.

Consecutive number Product Brand Dimensions, mm Cement brand Consumption of materials Products weight, t
L D1 D2 d1 d2 Concrete, m3 Steel, kg
1 CS 13,6-02-8 13600 330 470 204 334 В30(М400) 0,973 239,68 2,6705
2 CS 13,6-02-8э 13600 330 470 204 334 В40(М500) 0,9656 242,51 2,6705

CS – conical stand

Note:
1) Installation of embedded part according to the drawing is possible;
2) Stand CS 13,6-02-8э used in energetic building, is produced on basis of CS 13,6-02-8.

Stands are designed for use:
With design temperature of external air (the coldest five-day construction zone in accordance with SNIP 2.01.01.-82) to – 550P inclusive;
In I-VII areas for wind pressure and IV in the areas for the wall thickness of glaze according to the SNIP 2.01.07-85;

Stands are designed for use:
With design temperature of external air (the coldest five-day construction zone in accordance with SNIP 2.01.01.-82) to – 550P inclusive;
In I-VII areas for wind pressure and IV in the areas for the wall thickness of glaze according to the SNIP 2.01.07-85;
In seismicity of the construction site of a 9-point inclusive.

Send massage Download catalog